A newer Lp(a)-cholesterol assay adds no predictive value over standard Lp(a) mass testing, a WOSCOPS nested case-control study of 238 controls and 108 cases (Atherosclerosis 2000)
Original title: Is lipoprotein(a)-cholesterol a better predictor of vascular disease events than total lipoprotein(a) mass? A nested case control study from the West of Scotland Coronary Prevention Study
This nested case-control study within the placebo arm of the West of Scotland Coronary Prevention Study (WOSCOPS) compared a newer Lp(a)-cholesterol (Lp(a)-C) assay with routine Lp(a) mass measurements in 238 controls and 108 patients who had a serious vascular event. Lp(a) mass was measured by ELISA within 2 years of sampling and re-measured by immunoturbidimetric assay about 8 years later, alongside Lp(a)-C and apo(a) isoform size measurements on the same stored samples. Lp(a)-C and Lp(a) mass provided identical information, being equally non-discriminatory between cases and controls; the only difference between groups was the percentage of null apo(a) alleles (25.6% controls vs 19.4% cases). The findings confirm concordance between the two assay systems and show the Lp(a)-C assay adds no information beyond traditional Lp(a) mass assays, which may be faster and cheaper.
Original abstract
The clinical utility of a new assay for plasma lipoprotein(a)-cholesterol (Lp(a)-C) was assessed in parallel with our routine Lp(a) mass measurements in a nested-case control study of subjects within the placebo arm of the West of Scotland Coronary Prevention Study (WOSCOPS). A total of 238 control patients and 108 patients who had suffered a serious vascular event during the course of the WOSCOPS were examined. Lp(a) mass was assessed within 2 years of sampling by an ELISA method on baseline EDTA plasma samples which had been stored at -70 degrees C. Subsequently, the Lp(a) mass was re-measured by an immunoturbidimetric assay approximately 8 years after sampling. On the same stored aliquot the Lp(a)-C was measured. These analyses allowed us to assess whether the Lp(a)-C assay could provide any additional information over and above that which would be obtained from our Lp(a) mass assays. In addition the apo(a) isoform sizes of these subjects were measured using a high resolution immunoblotting system. The Lp(a)-C and Lp(a) mass measurements provided exactly the same information in the study, as they were equally non-discriminatory between cases and controls. The only difference between the two patient groups was the percentage of 'null' apo(a) alleles (control: 25.6% versus cases: 19.4%). We conclude that these results reinforce the concordance of the two assay systems and confirm that the Lp(a)-C assay provides no added information over and above that gained from traditional Lp(a) mass assays, which may be faster and less expensive.
Summary written by lp-a.org from the published abstract; figures as published. Page updated 18 August 2026. Methods.